Maico Final installation set PP 45 O
€466.10
Bezahlen Sie sicher und schnell mit:
Version:
- with the Unit can a complete Ventilation system after DIN 1946-6 incl. Extract air unit via a central Control (RLS 45 K) constructed are.
- With manually Damper.
- Via itself Commissioning Software at Use the RLS 45 K Control facilitates the Commissioning. Settings can stored and on additional Control transmitted are.
Optional Accessories:
- Wall block PP 45 MB
- Power part PP 45 LT
- EnOcean Extension module PP 45 EO
- EnOcean-Actor PP 45 ACT
- Humidity sensor PP 45 HYI and PP 45 HY
- CO2-Sensor PP 45 CO2
- VOC-Sensor PP 45 VOC
- Air filter, Replacement PP 45 G2, PP 45 G3 and PP 45 G2P
Approvals and Certificates:
- DIBt Approval Z-51.3-416.
- Test report after EN 13141-8.
- Entry in TZWL Bulletin.
Heat exchanger:
with the High power heat exchanger and the highly efficient EC Fan achieve the Units a Heat recovery efficiency of 84,3 % at the Reference airflow rate after EN 13141-8.
Installation instructions:
Installation takes place in 2 Steps:
Installation the Rough-in sleeve PP 45 RHK (DN 160) or PP 45 RHL (DN 160) as well as a External cover in a Core drilling DN 160 with a Inclination of 1-2 %.
We recommend the Core drilling with DN 182 to be carried out and the Inclination the Sleeve using included Polystyrene wedges to align.
The Rough-in sleeve is with Plaster-protection covers before Contaminants protected.
Subsequently follows the Integration of the Final installation sets.
No Pipe installation required and no Balancing the System required.
Electrical Connection:
- The Unit is operation finished installed supplied.
- Electrical Connection takes place using Push-fit connection.
- Connection for the Room air control RLS 45 K or RLS 45 O via plug-in Control cables.
- The 12 VDC Power cable the Room air control RLS 45 K / RLS 45 O for the Unit is simultaneously the Control cable.
Condensate drain:
The Discharge of the Condensate takes place via a integrated Condensate drip edge in the External cover.
Special Properties:
The Units series PP 45 K/O/RC is the quiet Units series on the Market and impresses with the Sound-pressure level values (per Ventilation level and Distance 1 m): 21 dB(A) / 25 dB(A) / 31 dB(A) / 35 dB(A) / 38 dB(A).
The Energy efficiency of two Unit + Control impresses with a SPI-Wert of max. 0,12 Wh/m³.
Through the very quiet and energy-saving Motors, a very good sensor-controlled Operation achieve the Units the Energy efficiency class of A+.
The Pipe insertion can tool-free to Cleaning purposes and for the Filter replacement removed are. The two Filter are also tool-free replaceable.
The Heat exchanger can with Help a Tool also to Cleaning purposes removed are.
The Units can in 5 different Ventilation levels 15/20/30/36/42 m³/h and in 3 Operating program Continuous extract ventilation with heat recovery, Cross ventilation and sensor-controlled Automatic mode operated are.
Flow-optimized External cover in the Accessories range hold the Extract air of the Outside fascia fern.
Features:
Final installation sets for the Single-room ventilation unit PushPull 45 with Fan, Ceramic Heat exchanger, Inside cover and two integrated Filter (ISO Coarse 30 % (G2) and ISO Coarse 45 % (G3)), so that the Air in both Directions filtered is.
By a efficient Ventilation to achieve, recommend we the Units in pairs to operate.
In specific System combination is also a odd Number of Unit possible.
Required Accessories:
- Rough-in sleeve PP 45 RHK or PP 45 RHL
- External cover PP 45 AK, PP 45 AE, PP 45 AW, PP 45 AS, PP 45 AKR or PP 45
- AKB for Outside wall mounting or Reveal element PP 45 LE for Reveal duct installation.
- Room air control RLS 45 K or RLS 45 O for the Final installation sets PP 45 K and PP 45 O and Wireless switch DS 45 RC for the Wireless device PP 45 RC.
Via a Room air control RLS 45 K or RLS 45 O can several Units (max. 6) simultaneously controlled are.
- At Use of the Wireless switch DS 45 RC is the Units number not limited, provided that the Units itself in Range the Wireless switch are located.
Dokumente
| Degree of protection: | IP 00 |
|---|---|
| Nominal pipe diameter: | 160 mm |
| Height: | 246 mm |
| Width: | 246 mm |
| Material: | Housing made of Plastic; Heat exchanger made of Ceramic |
| Airflow rate: | 15 / 20 / 30 / 36 / 42 m³/h |
| Color: | traffic white, similar RAL 9016 |
| Depth: | 282 mm |
| Installation: | Wall |
| Other: | Filterklasse: ISO Coarse 80 % (G4) / ISO ePM1 60 % (F7) |
| Rated power: | 0,0012/0,0017/0,0021/0,0028/0,0035 kW |