Maico Final installation set PPB 30 K
€658.02
Bezahlen Sie sicher und schnell mit:
Approvals and Certificates:
- Test report after EN 13141-8.
- Entry in TZWL Bulletin.
Heat exchanger:
with the High power heat exchanger and the highly efficient EC fans achieve the Units a Heat recovery efficiency of 73 % at the Reference airflow rate after EN 13141-8.
Installation instructions:
Installation takes place in 2 Steps:
Installation the Rough-in sleeve PP 45 RHK (DN 160) or PP 45 RHL (DN 160) as well as a External cover in a Core drilling DN 160 with a Inclination of 1-2 %.
We recommend the Core drilling with DN 182 to be carried out and the Inclination the Sleeve using included Polystyrene wedges to align.
The Rough-in sleeve is with Plaster-protection covers before Contaminants protected.
Subsequently follows the Integration of the Final installation sets.
No Pipe installation required and no Balancing the System required.
Electrical Connection:
- The Unit is operation finished installed supplied.
- Electrical Connection takes place using Push-fit connection.
- Connection for the Room air control RLS 45 K or RLS 45 O via plug-in Control cables.
- The 12 VDC Power cable the Room air control RLS 45 K / RLS 45 O for the Unit is simultaneously the Control cable.
Condensate drain:
The Discharge of the Condensate takes place via a integrated Condensate drip edge in the External cover.
Special Properties:
The PPB 30 K Unit is a perfect Supplement for PP 45 K/O Units by a Ventilation system after DIN 1946-6 via a central Control (RLS 45 K) to build.
The PPB 30 K Units have as standard a Humidity sensor and are primary for installation in the Extract air rooms designed. The Degree of protection IP X4 facilitates the Selection of the Installation location in the Bathroom.
The Energy efficiency from the PPB 30 K impresses with a SPI-Wert of 0,19 Wh/m³.
Through the energy-saving Motors, a very good sensor-controlled Operation achieve the Units the Energy efficiency class of A.
The PPB 30 K Unit can in 5 Ventilation levels 5/12/18/22/26 m³/h and 3 Operating mode Continuous extract ventilation with heat recovery, Cross ventilation without Heat recovery and Automatic control operation operated are.
The recommended Combination option is 2 x or. 4 x PP 45 K/O + 1 x PPB 30 K + 1 x RLS 45 K. In this Fall can the PPB 30 K Unit in two different Operating modes operated are. in the Automatic mode operates the Unit complete standalone in Dependence of the Humidity value from the integrated Sensor. in the Automatic mode are of the Room air control RLS 45 K only the Commands „External Made of“ and „Ventilation level 0“ designed.
in the System operation operates the Unit complete after Specifications the Room air control RLS 45 K. Only in the Trap the Humidity load (Limit value adjustable) couples itself the Unit from the System off and starts the Dehumidification. The Dehumidification automatic control can as Intensive ventilation operation (Stage 5 with heat recovery) or as Extract air operation (45 m³/h without Heat recovery) set are.
in the Trap the Odour load can the Intensive ventilation operation (Stage 5 with heat recovery) or Extract air operation (45 m³/h without Heat recovery) likewise manually with a Push button/Switch triggered are. The Duration this Function is adjustable (Factory setting = 10 min).
in the Trap of the Extract air operation from the PPB 30 K ensure the at the Room air control RLS 45 K connected PP 45 K/O Units for the required Supply air. The Combination of PPB 30 K and Extract air unit (z.B. ER/ECA) at a Room air control RLS 45 K is not possible.
Via itself Commissioning Software at the Use the RLS 45 K Control facilitates the Commissioning the PPB 30 K Units. In the process can the Settings as Profile stored and on additional Control transmitted are.
Flow-optimized External cover in the Accessories range hold the Extract air of the Outside fascia fern.
Features:
Final installation set for the Single-room ventilation unit PushPull Balanced PPB 30 with two Fans, two Ceramic heat exchanger, Inside cover and two integrated Filter ISO Coarse 45 % (G3), so that the Air in both Directions filtered is.
Required Accessories:
- Rough-in sleeve PP 45 RHK or PP 45 RHL
- External cover PPB 30 AK, PPB 30 AE, PPB 30 AW or PPB 30 AS
- Room air control RLS 45 K. With a Room air control RLS 45 K can man a wired Ventilation system made of PPB 30 and PP 45 Unit assemble. The maximum Number the used Fans is 6. Thus are various Combination possible, z.B. 2 x PP 45 K/O + 1 x PPB 30 K + 1 x RLS 45 K or 3 x PPB 30 K + 1 x RLS 45 K. A Combination of PPB 30 K and RLS 45 O is not permissible.
Optional Accessories:
- Extension set PPB 30 VS
- Wall block PP 45 MB
- Compensation frame PPB 30 ARE and PPB 30 ARW
- Mounting sheet metal PPB 30 ARE BB and PPB 30 ARW BB for Compensation frame
- Humidity sensor PP 45 HYI and PP 45 HY
- CO2-Sensor PP 45 CO2
- VOC-Sensor PP 45 VOC
- Air filter, Replacement PPB 30 G3
- The Room air control RLS 45 K can with the internal Humidity sensor PP 45 HYI or with the external Sensor PP 45 HY, PP 45 CO2 and PP 45 VOC extended are. In the process achieve the Units the Energy efficiency class A.
The Room air control RLS 45 K can in 5 Ventilation levels 5/12/18/22/26 m³/h and 3 Operating mode Continuous extract ventilation with heat recovery, Cross ventilation without Heat recovery and Automatic control operation operated are.
Dokumente
| Degree of protection: | IP X4 |
|---|---|
| Nominal pipe diameter: | 160 mm |
| Height: | 275 mm |
| Width: | 275 mm |
| Material: | Housing made of Plastic; Heat exchanger made of Ceramic |
| Airflow rate: | 5 / 12 / 18 / 22 / 26 m³/h |
| Color: | traffic white, similar RAL 9016 |
| Depth: | 410 mm |
| Installation: | Wall |
| Other: | integrierter Feuchtesensor |
| Rated power: | 0,0017/0,0025/0,0034/0,0044/0,0053 kW |